How to Select Explosion Proof Equipment for Tank Farms and Terminals
To select explosion proof equipment for a tank farm or terminal, start with the hazardous-area classification for each installation point, then match the equipment’s protection marking, gas group, temperature class, environmental rating, and electrical requirements to that location. Do not choose equipment from a product name or enclosure rating alone: the correct selection depends on the substances present, the likelihood and duration of a hazardous atmosphere, local regulations, and the site’s operating conditions. Have a qualified project or safety professional confirm the area classification and applicable code before purchase. We recommend preparing this information first so suppliers can assess fit and quote accurately.
Click here to get more.
Key Takeaways
- Obtain the hazardous-area classification and required protection method for each equipment location before requesting quotations.
- Check the complete product marking against the site’s gas or vapor group, temperature class, zone or division, and jurisdictional requirements.
- Confirm environmental, electrical, mounting, cable-entry, and maintenance needs separately; an IP rating does not by itself indicate explosion protection.
- For lighting, consider the hazardous-area marking alongside illumination needs, mounting height, controls, and maintenance access.
Step 1: Define the Equipment Location and Hazard
Tank farms and terminals contain different operating areas, and they should not be treated as one uniform hazardous location. Potential locations include tank roofs, loading racks, pump areas, process connections, and control or maintenance spaces. Whether a particular point is classified as hazardous depends on the site design, substances handled, release sources, ventilation, and governing rules. Use the site’s area-classification documents rather than assuming that every location near a tank has the same classification.
Gather the Site Classification Information
For each proposed installation, record the zone or division, gas or vapor group, and temperature class where applicable. Also identify the hazardous substance and any project-specific requirements for the equipment protection concept. Requirements differ between regulatory systems, so confirm whether the project follows IEC-based, North American, or another applicable framework. If classification details are incomplete, ask the responsible engineer to clarify them before selecting products.
Step 2: Match the Protection Marking to the Project
Compare the marking on each product with the classification documents and the requirements of the installation jurisdiction. The marking should provide the information needed to establish suitability, such as the protection concept and the applicable group, temperature class, and zone or division. Do not assume that equipment accepted under one certification scheme is automatically approved for another market. Request product documentation and have the project’s qualified reviewer confirm that the complete marking is acceptable.
Understand the Limits of Enclosure Ratings
An IP rating describes protection against ingress of solids and water under defined test conditions; it does not establish that equipment is suitable for an explosive atmosphere. Similarly, a rugged housing or sealed cable entry does not replace the required hazardous-area protection. Review environmental protection and explosion protection as separate selection criteria. This distinction is important for outdoor equipment exposed to rain, dust, washdown, or coastal conditions.
Step 3: Check Electrical and Environmental Requirements
Confirm the supply voltage, frequency, power, wiring method, grounding requirements, and control interfaces before specifying equipment. For example, a project may use a 230 V AC supply, but that is only an illustrative value; the actual voltage must be taken from the site electrical design and the product nameplate. Check that cable glands, conduit entries, and connection accessories suit both the equipment and the installation method. A mismatch can create installation delays or require redesign.
Record the expected ambient temperature range, exposure to sunlight, moisture, dust, vibration, and corrosive chemicals. As an example of a project input—not a universal operating limit—a specification might require equipment suitable for ambient conditions from -20°C to +50°C. The manufacturer’s stated limits and the project’s hazardous-area requirements must both be satisfied. Also consider whether the installation is accessible for inspection and maintenance without disrupting terminal operations.
For more information, please visit MASCO.
Step 4: Select Equipment for the Specific Duty
Build the equipment list by function, then assess each item at its intended location. A terminal may need hazardous-area lighting, junction boxes, control stations, luminaires, or other electrical equipment, but each product must be evaluated against its own operating and installation requirements. Avoid assuming that one product family or protection marking covers every device on the site. Where equipment interfaces with a control or safety system, coordinate its electrical and functional requirements with the relevant design team.
For LED Explosion-Proof Lights
When selecting LED explosion-proof lights, first confirm the area classification and required product marking; then assess the lighting task, mounting position, beam distribution, glare, and maintenance access. The required light level should be established by the project’s lighting design for the task and location, rather than inferred from wattage alone. Check input voltage, driver compatibility, operating temperature, mounting hardware, cable entries, and any dimming or emergency-lighting requirements. If lights operate for 10 hours per day, the planned schedule represents 3,650 operating hours per year, so access for inspection and maintenance should be considered during layout.
Step 5: Compare Suppliers and Prepare an RFQ
A useful request for quotation gives suppliers enough detail to identify a suitable product without guessing. Include the location and area classification, applicable standards or approval requirements, supply details, ambient conditions, mounting method, cable-entry specification, and quantity. For example, state whether a 20 mm cable entry is required only when that dimension is confirmed by the project design; do not assume it is interchangeable with a different entry size. Attach drawings, schedules, or equipment lists when available.
Ask suppliers to provide the relevant datasheet, product marking, installation instructions, dimensional information, and available configuration options for review. Request clarification where a proposed product’s documentation does not clearly address a project requirement. We at MASCO can review application details for LED explosion-proof lighting and help identify the product information needed for technical evaluation and quotation. Final acceptance should remain with the project’s qualified engineer or designated approval authority.
Key Decision Points Before You Order
- Area suitability: Does the complete product marking match the location classification and applicable jurisdiction?
- Temperature and substance compatibility: Are the marked temperature class and group appropriate for the documented hazard?
- Electrical fit: Do voltage, frequency, wiring, control, and connection details match the site design?
- Environmental fit: Are ingress protection, materials, temperature limits, and mounting suitable for the actual conditions?
- Lifecycle considerations: Can the equipment be inspected, maintained, and replaced safely within the site’s operating plan?
Common Selection Mistakes
- Choosing by “explosion proof” wording alone: A general product description cannot replace verification of the exact marking and approvals required.
- Using IP rating as proof of hazardous-area suitability: Ingress protection and explosion protection address different risks.
- Applying one classification across an entire facility: Conditions can differ by location, so use the site documentation for each installation point.
- Ignoring accessories and installation details: Cable glands, entries, brackets, and wiring methods must be compatible with the selected product and project design.
- Requesting a quote without technical inputs: Missing classification, voltage, or environmental information can lead to unsuitable proposals and avoidable revisions.
Improve Selection and Project Coordination
Use a location-by-location equipment schedule to connect each device to its classification, function, electrical supply, and environmental requirements. Ask engineering, operations, maintenance, and procurement teams to review the schedule before the purchase order is released. This helps surface practical issues such as access, mounting constraints, spare-parts planning, and shutdown windows early. Keep the approved product documentation with the project records so installation and future maintenance teams can verify what was specified.
Conclusion: Select from Verified Site Requirements
The reliable way to select explosion proof equipment for tank farms and terminals is to begin with the documented hazardous-area classification, match the product’s full marking and electrical characteristics, and then confirm environmental and installation fit. For LED lighting, include the lighting task and maintenance plan alongside explosion protection; do not select by wattage or enclosure rating alone. Before requesting a quotation, assemble the classification details, supply information, ambient conditions, mounting requirements, and quantities. Contact MASCO with these project inputs to discuss LED explosion-proof lighting options and request product documentation for your technical review.